Item No. 12203
The Aimpoint® CEU (Concealed Engagement Unit) gives the operator the ability to observe and/or engage a threat from a concealed or covered position. The Aimpoint CEU easily rotates from side to side, so an operator can safely look around either right or left-hand corners, over barricades and under vehicles. It can also be quickly removed in order to rapidly return to direct engagement.
The Aimpoint CEU rotates a full 260° allowing the operator to safely look around either right or left-hand corners, up staircases or down tunnels from almost any angle. To mount the CEU, use the Aimpoint TwistMount base and choose the CEU ring which allows co-witnessing with the Aimpoint sight.
Launched 2009.
| General Specifications |
|---|
| Item No.: 12156 |
| Optical Specifications |
|---|
| Operating principle: Dual mirror reflective device for true target view |
| Optical magnification: 1x |
| Aiming dot size: Uses the reticle of the combining sight |
| Optical signature: No optical signature |
| NVD compatible: No |
| Clear aperture: 25 mm (1 in) |
| Eye relief: Unlimited |
| Power Source |
|---|
| Battery type: No power required |
| Physical Specifications |
|---|
| Length conf: 90 mm (3.6 in) |
| Width sight only: 115 mm (4.5 in) |
| Height sight only: 40 mm (1.6 in) CEU only, detached from the CEU Rise Ring and TwistMount base |
| Height conf: No standard config, can be mounted with 2 different configs. |
| Weight sight only (incl battery): 130 g (4.6 oz), CEU only |
| Weight conf: With Low Top ring 165 grams (5,8 oz). With High Top ring 185 grams (6,5 oz). |
| Housing material: High strength glass reinforced polymer |
| Housing finish and color: Grey, non-glare finish |
| Material mount and spacer std conf: Used with either the CEU High- or Low Rise Ring |
| Surface treatment: Rubber, black, non-glare finish |
| Height of optical axis - sight and mount: 30 mm (1.2 in) (CEU Low Rise Ring) |
| Height of optical axis - sight, mount and low spacer: 39mm (1.5 in) (CEU High Rise Ring) |
| Adjustment: Rotation around optical axis: ±130°, measured from CEU pointing vertically upwards |
| Environmental Specifications |
|---|
| Temperature range operation: +5°C to +55°C (+41°F to +131°F) |
| Temperature range storage: -51°C to +71°C (-60°F to +160°F) |
| Humidity: Operable during and after Humidity. Limits: RH: 95%, Temp: +20°C to +50°C (+68°F to +122°F), cyclic |
| Submersible: To a depth of 25 m (80 ft.) |
| Shock: Withstands shock. Limits: X-axis: 500 g, 0.7 – 1.1 ms (3 shocks), Y-axis: 40g ±4g, 11 ±1ms (2 shocks in each direction, Z-axis: 40g ±4g, 11 ±1ms (2 shocks in each direction). |
| Vibration: Withstands Vibration. Limits: Vibration, sinusoidal in a frequency range of 10-150 Hz. Frequency: 10-30 Hz, ±1.587 mm, Frequency: 30-150 Hz. 5.75 g, 1 octave/min. Direction: X, Y and Z, Time: 30 min/direction. |